Try the following steps, in this order, until the telescopes are in a safe position, i.e. approximately horizontal.
 
Try the following steps, in this order, until the telescopes are in a safe position, i.e. approximately horizontal.
 
* Run the command  ''slew stow''  in any terminal window on the TCS machine (computer keyboard/screen nearest the door). The username/password is written on the white board.  
 
* Run the command  ''slew stow''  in any terminal window on the TCS machine (computer keyboard/screen nearest the door). The username/password is written on the white board.  
* If this command does not work, try the command "park" in any terminal window.  
+
* If this command does not work, try the command ''park'' in any terminal window.  
* Check that the telescopes are out of the way of the roof. If not, use a 13mm spanner to loosen-off the RA and Dec drive clamps and move the telescopes to a safe position by hand. Remember to tighten (but don't over-tighten) the drive clamps afterwards. There is a tool box on the floor in the mount room.  
+
* Check that the telescopes are out of the way of the roof. If not, use a 13mm spanner to loosen-off the RA and Dec drive clamps and move the telescopes to a safe position by hand. Remember to tighten (but don't over-tighten) the drive clamps afterwards. There is a tool box on the floor in the mount room.
  
 
==== Close the roof ====
 
==== Close the roof ====

Revision as of 01:03, 20 March 2022

How to close the roof without breaking the telescopes

First put the telescopes in a safe position

Try the following steps, in this order, until the telescopes are in a safe position, i.e. approximately horizontal.

  • Run the command slew stow in any terminal window on the TCS machine (computer keyboard/screen nearest the door). The username/password is written on the white board.
  • If this command does not work, try the command park in any terminal window.
  • Check that the telescopes are out of the way of the roof. If not, use a 13mm spanner to loosen-off the RA and Dec drive clamps and move the telescopes to a safe position by hand. Remember to tighten (but don't over-tighten) the drive clamps afterwards. There is a tool box on the floor in the mount room.

Close the roof

Try the following steps, in this order, until the roof is closed.

  • On the observer machine, enter the command "close_roof" in any terminal window. (Same username/password as tcs).
  • If this does not work, use the grey box on the wall of the computer room to close the roof.
  1. Press "START" to power-up the hydraulics
  2. Hold the "CLOSE" button until the roof is closed
  3. Press "STOP" to shut-down the motor.
  4. Twist the STOP button to release it when you have finished.
  • In an emergency only e.g. if there is no power, you can use the spanner next to the box WEATHER STATION POWER SUPPLY to undo the 3 bolts that hold the roof onto the hydraulic ram and push the roof closed by hand (this is a two-person job).