Difference between revisions of "SHOCnWonder"
(→Specifications) |
(→Specifications) |
||
Line 8: | Line 8: | ||
*'''Camera''': [[Media:Andor-ixon-ultra-emccd-specifications.pdf|Andor iXon 888 #BV USB3]] , 1024 × 1024px CCD, 13 μm pixels ([[Media:Shocnwonder_spec_sheet.pdf|CCD performance test sheet]]) | *'''Camera''': [[Media:Andor-ixon-ultra-emccd-specifications.pdf|Andor iXon 888 #BV USB3]] , 1024 × 1024px CCD, 13 μm pixels ([[Media:Shocnwonder_spec_sheet.pdf|CCD performance test sheet]]) | ||
*'''Plate scale:''' 0.16 arcsec/px | *'''Plate scale:''' 0.16 arcsec/px | ||
− | *'''Field of view:''' 2.7' × 2.7' (the new system has a | + | *'''Field of view:''' 2.7' × 2.7' (the new system also has a focal reducer so the FoV-width is roughy double than the old system) |
*'''Filters:''' | *'''Filters:''' | ||
*:'''Filter Slide A:''' U,B,V,R,I | *:'''Filter Slide A:''' U,B,V,R,I |
Revision as of 10:51, 23 February 2024
Contents
Introduction
This page contains additional information for the "new SHOC" aka "shocnwonder" that is now permanently mounted on the 74-inch as a secondary instrument via the 74-inch "Instrument Selector" so user should first familiarise themselves with the "Instrument Selector" wiki: wiki-link.
All the hardware for the new SHOC system is new but the underlying control software, GUI, service startup instructions, and data-folder structures etc. are identical to the old SHOC systems so user should also first familiarise themselves with the old SHOC wiki if they are not already regular SHOC users: wiki-link.
Specifications
- Camera: Andor iXon 888 #BV USB3 , 1024 × 1024px CCD, 13 μm pixels (CCD performance test sheet)
- Plate scale: 0.16 arcsec/px
- Field of view: 2.7' × 2.7' (the new system also has a focal reducer so the FoV-width is roughy double than the old system)
- Filters:
- Filter Slide A: U,B,V,R,I
- Filter Slide B: Currently unpopulated but eventually will have u', g', r', i', z'
GUI and login details
GUI url (onsite or via VPN access only): http://shocnwonder.suth.saao.ac.za:5000/ OR http://shoc74in.suth.saao.ac.za:5000/
username: shoc74in
password: the regular "shoc74in" user password
Data access
There is a automated log being generated as files appear on disk by scraping the fits headers:
https://www.saao.ac.za/~sbp/74in_SHW_ObsLogs/
As with the old SHOC systems, data can be copied as follow:
- Open a shell on your local PC (Putty if you're using Windows or a bash/tcsh/sh if on Mac or Linux)
- Copy the data using the following command:
rsync -avzP shoc74in@shoc74in.suth.saao.ac.za:"/data/74in/shw/<YYYY>/<MMDD>/*.fits" /LocalFilePath ---- the password is that for the shoc74in accounts
- NOTE: if the rsync command fails, try it WITHOUT the wildcard (*) and specify a specific file. Some rsync programs apparently do not support this function.