** Now, run '''IRAF - twodspec - identify''' on the corresponding raw 2D image. Select the same line and input its wavelength as just read off the plot. The solution is good to within a couple of Angstroms, and there are sufficient lines in the arcs that this should work well. | ** Now, run '''IRAF - twodspec - identify''' on the corresponding raw 2D image. Select the same line and input its wavelength as just read off the plot. The solution is good to within a couple of Angstroms, and there are sufficient lines in the arcs that this should work well. | ||
''Hint: remember that the raw and 1D Extracted spectra are flipped. A good trick is to reverse the plot window in IRAF with 'w' 'e' 'e' by selecting from bottom right to top left''' | ''Hint: remember that the raw and 1D Extracted spectra are flipped. A good trick is to reverse the plot window in IRAF with 'w' 'e' 'e' by selecting from bottom right to top left''' | ||
+ | ** Repeat for several lines. | ||
+ | ** When happy, automatically add all the lines (press "l"). | ||
<gallery> | <gallery> | ||
plotIRAF1.png|python plot window next to IRAF identify window | plotIRAF1.png|python plot window next to IRAF identify window | ||
plotIRAF2.png|After flipping IRAF identify window in x, it is now straightforward to match lines by eye | plotIRAF2.png|After flipping IRAF identify window in x, it is now straightforward to match lines by eye | ||
+ | identifyAll.png|After matching ~5 lines, fitting, and pressing 'l' to auto-identify the rest | ||
</gallery> | </gallery> | ||
− | |||
− | |||
* Once you have identified the lines in one aperture, repeat for every nth pixel (probably every 5th pixel is fine, the tilt is about 0.6 pixels per pixel) using '''reidentify'''. | * Once you have identified the lines in one aperture, repeat for every nth pixel (probably every 5th pixel is fine, the tilt is about 0.6 pixels per pixel) using '''reidentify'''. | ||
* Run '''fitcoords''' on the database produced by reidentify | * Run '''fitcoords''' on the database produced by reidentify |
Revision as of 13:38, 22 December 2016
Contents
Overview
The QL Tool produces quick-look products, but there are some straightforward steps allowing users to use these as a starting point for their science quality reductions
Important Notes
In going from the raw 2D images to the 1D extractions produce by the QL Tool:
- The x axis is flipped so that increasing wavelength runs in the same direction as increasing x
- The spectra are then trimmed to remove overscan, etc.
For IRAF users
Since most observers seem to have their own scripts from the old version of the spectrograph, the easiest way to reduce the data is to use the QL wavelength calibrated outputs as a reference for an IRAF reduction of the raw data.
i.e.
- Perform all the pre-processing steps as you would normally on the raw 2D data.
- When you are ready to wavelength calibrate an arc, do so as follows:
- Use the QL output as a reference. For example, a useful way is to plot the ascii wavelength solution in some interactive plotting window, like python.
- Then simply, select a few bright, well-spaced lines, hover the cursor over them, and read off the wavelength coordinate.
- Now, run IRAF - twodspec - identify on the corresponding raw 2D image. Select the same line and input its wavelength as just read off the plot. The solution is good to within a couple of Angstroms, and there are sufficient lines in the arcs that this should work well.
Hint: remember that the raw and 1D Extracted spectra are flipped. A good trick is to reverse the plot window in IRAF with 'w' 'e' 'e' by selecting from bottom right to top left'
- Repeat for several lines.
- When happy, automatically add all the lines (press "l").
- Once you have identified the lines in one aperture, repeat for every nth pixel (probably every 5th pixel is fine, the tilt is about 0.6 pixels per pixel) using reidentify.
- Run fitcoords on the database produced by reidentify
- Run transform on the image using the fitcoords database to produce a wavelength-calibrated, rectified 2D arc.
- This solution may now be copied to other images and science data extracted in the standard way!
Advanced notes for users wishing to code up their own routines using these output files
- The spectra are then trimmed to remove overscan, etc.
The exact values for these are stored in:
/usr/local/etc/qlgui/pars.json
"badMax0": 98,
"badMin1": 2145,
in python 0-based numbering.
i.e. in python, to reproduce the same transformation, one would do:
from astropy.io import fits
import numpy as np
im2D = fits.getdata('image.fits')
im2D = np.fliplr(im2D[:,::-1])[:,98:2145]
fits.writeto('outimage.fits',im2D)
This image could then be used for a fresh extraction using IRAF or the user's preffered package, and will be one-to-one pixel aligned with the [approximate] WLC from the 1D extracted arc.
In IRAF, the equivalent would be:
imcopy a0361665[-*,*] test.fits
imcopy test.fits[99:2146,*] out65.fits
[Note the 1-based indexing]
ZZZ interactive WLC examination in IRAF
ZZZ cl script for flipping images and attaching WLC to arcs