,==SPUPNIC ON==
'''In the Warm Room:'''
Install the computer systems as per Fig. 7 below.
* Fire up the TCS software and check functionality as follows:
# Check that the XY slide initializes correctly (reset button on the emergency stop box on the north pier)
# Lodestar Acquisition CCD camera operational – start exposures, check the readout occurs properly. (Note that the regular control box for the acquisition mirror is empty since it is not present.)
* On the SpUpNIC computer:
# Ensure that the SpUpNIC fibre is plugged in. When the fibre is correctly connected AND BOTH the computer and CCD controller are powered up, a green LED is ON on the interface (Fig 8).
# Ensure the dual monitors, keyboard & mouse are connected.
# Ensure the LAN cable and RS232 connector (to the PLC) are connected (Fig. 8).
* Check that the Lodestar industrial PC is installed (Fig. 7).
* At the back of the TCS-rack:
# check that the RS232 PLC cable is connected to the fibre, and the channel selector switch is correctly set (Fig 9, bottom insert box).
# check that the USB connection to the Lodestar rear-of-slit camera is plugged in to the USB-to-fibre convertor (Fig. 9, top insert box).
# check that the USB connection to the Lodestar acquisition camera is plugged in to the USB-to-fibre convertor, located on the right-hand side of the rear-of-slit camera fibre convertor.